2020 … 2021 Herscheid – Doubling of the volume flow at the vacuum precoat filter

The Kükelhaus School in Magdeburg, the building was 2009 built. For the children and young people a pool was designed with height-adjustable floor. As a base, a concrete construction should serve, which are lined in the system "Myrthapools" and with a height movable floor (Hubboden) should be equipped.

Who can not calculate, takes Tichelmann*!

The system of the pool hydraulic Tichelmann is widespread and can often be used without special calculations. But what, if thepool is not rectangular or relative 1:2 was built or even designed with curves in the pool wall from architects? In the article, the newspaper of the Federal Association of German Schwimmmeister “Das Schwimmbad und sein Personal” edition 02/2019 a note is given to the methods of calculation.

Let's start the INTERNET OF WATER!

Internet of things is literally on everyone's lips, and describes, such as the Internet in equipment has arrived. In our industry, you might think, IOT aviod the pools. We should change that together! Maybe it just needs a new slogan for it, as industry 2.0 or GroKo (german for big Coalition), in which the name is more powerful than the content. The chemical basis for disinfection have not changed significantly, we will address these fundamentals. How can a own Internet of water build up in each pool , but will play a major role in the following.

Pool construction types 02 Theorems

1. Quotation DIN 19643, section 4: “For disinfecting, a germ killing of Pseudomonas aeruginosa by four orders of magnitude was within 30 s used.” Even if you think, this sentence could not relate to the swimming pool: This theorem is the basis of any further consideration! This theorem describes the effect of the disinfectant chlorine at a concentration of between 0,3 and 0.6 mg/l. All other theorems are built up on this foundation. This theorem is also true for water treatment.

Pool construction types 03 Waterproof concrete

This construction is in Germany often as “White Tank” called. It is initially for the construction of basements (in groundwater) systems used. Bottom plate and outer walls of a closed tank made of concrete with a high water penetration resistance in accordance with DIN EN 206-1 and DIN 1045-2 manufactured. This concrete is also called water-impermeable concrete or waterproof concrete. Expertise and careful approach to planning and construction are key to a proper and even dense basement.