Seminar chlorine dioxide generators

Seminar for measurement of disinfectants in water with the following contents: Introduction water disinfection, Measurable disinfectant, Connection pH and disinfecting action of chlorine and bromine, Principle of amperometric measurement with and without membrane, Construction membrane-covered sensors, Conditions of measurement, Cross-sensitivities, Causes of any disturbance of the measurement, Signal transmission and signal types, Calibration of the connected controller, Maintenance and reconditioning of the electrochemical system of sensors.

Seminar controller DCW400ip – INTERNET OF WATER

Seminar zu Regler DCW400ip – INTERNET OF WATER; Introduction water disinfection, Measurable disinfectant, Connection pH and disinfecting action of chlorine and bromine, Influence of trichloro-isocyanuric acid on the measured value, Conventional methods for producing chlorine dioxide, Signal extracting with different sensor types, Available modules for the device and available measurement parameters, Connecting the device to the Internet, Advantages of the internal Web server, Activation of the modules, Setting of the sensor to the module, Configuration of the controller, Output configuration, Configuration of target value, Warning levels and alarm levels, Calibration of the instrument and the DPD measurement configuration of the timer functions, Configuration of all inputs on the main board and use of data, User Management, Email Management, evaluate statistical data,

Seminar membrane-covered amperometric sensors

Seminar for measurement of disinfectants in water with the following contents: Introduction water disinfection, Measurable disinfectant, Connection pH and disinfecting action of chlorine and bromine, Principle of amperometric measurement with and without membrane, Construction membrane-covered sensors, Conditions of measurement, Cross-sensitivities, Causes of any disturbance of the measurement, Signal transmission and signal types, Calibration of the connected controller, Maintenance and reconditioning of the electrochemical system of sensors.

From the craft of calibrating

From Craft calibration and the many pitfalls to these daily handles. In each water treatment facility of a public swimming pool needs to be done: Measuring and logging water chemistry. In previous articles, we have often discussed it, but always on the edge and not focused on the activities of calibration.

Let's start the INTERNET OF WATER!

Internet of things is literally on everyone's lips, and describes, such as the Internet in equipment has arrived. In our industry, you might think, IOT aviod the pools. We should change that together! Maybe it just needs a new slogan for it, as industry 2.0 or GroKo (german for big Coalition), in which the name is more powerful than the content. The chemical basis for disinfection have not changed significantly, we will address these fundamentals. How can a own Internet of water build up in each pool , but will play a major role in the following.

The advantages of membrane-covered amperometric sensors

If we talk about disinfection, then most people immediately think of "chlorine". Here is often overlooked, that chlorine in different forms occurs. While the right eye can be protected by "free chlorine" for infections, is the left eye may be the result of bounded chlorine and his children in the air. This bound chlorine is the reason for the bad taste and smell in the air - but has very little to do with the disinfection or our protection. Membrane-covered sensors can also detect this kind of chlorines.

The selection of membrane-covered amperometric sensors

Tutorial to choose Membrane covered amperometric sensors with detailed explanations of the parameters. In this table, you can select the correct sensor. In the footer of the table filter can be written, which restricts the number of rows. Please also note the informations, which will be displayed in the right columns by horizontal scrolling. Find out in the fields measuring size, Subgroup, Measuring range, Measuring water, Pressure, pH range, Temperature, Cross sensitivity, Reaction time, Connections, Downloads, about the existing possibilities and conditions.