2017 … 2019 Development of a web server-based modular controller

In the employee relationship within the Dosatronic GmbH in the position of Technical Director, the development of a regulator in the slogan "INTERNET OF WATER" I initiated, continued and completed the first target status. Previously, the DOSATRONIC GmbH has a variety of other brands bought and sold as an OEM product. The biggest weakness of these devices was the lack of communication with decentralized systems. As a second weakness, the communication with the operator via the line-oriented display was identified. So, the goal was a modular controller with an embedded Web server, which performs the communication based on HTML. The features of this controller are described in detail.

The advantages of membrane-covered amperometric sensors

If we talk about disinfection, then most people immediately think of "chlorine". Here is often overlooked, that chlorine in different forms occurs. While the right eye can be protected by "free chlorine" for infections, is the left eye may be the result of bounded chlorine and his children in the air. This bound chlorine is the reason for the bad taste and smell in the air - but has very little to do with the disinfection or our protection. Membrane-covered sensors can also detect this kind of chlorines.

The selection of membrane-covered amperometric sensors

Tutorial to choose Membrane covered amperometric sensors with detailed explanations of the parameters. In this table, you can select the correct sensor. In the footer of the table filter can be written, which restricts the number of rows. Please also note the informations, which will be displayed in the right columns by horizontal scrolling. Find out in the fields measuring size, Subgroup, Measuring range, Measuring water, Pressure, pH range, Temperature, Cross sensitivity, Reaction time, Connections, Downloads, about the existing possibilities and conditions.

error: Content is protected !!